# Asset Inspection Report Template

For the asset that justifies a scaffold, or avoids one

Editable asset inspection report template for drone surveys of chimneys, facades, bridges, silos and cranes: elements, graded findings and access constraints.

- **Document:** 06 General asset inspection
- **In:** Drone Inspection Report Template Pack, EUR 39 one-off - https://canfly.io/toolkit/drone-inspection-report-template
- **Stage of the job:** After the flight
- **Who asks for it:** The owner, managing agent or structural engineer deciding whether to pay for access
- **Format:** Editable .docx, rebrand and reuse on unlimited client work
- **Completed example, free:** https://canfly.io/toolkit/examples/chimney-inspection-report

## What it is

The adaptable report in the pack, written for assets that do not have a template of their own: chimneys and stacks, facades, bridges, silos, cranes, towers. It states overall condition for the asset's age and exposure, then records findings element by element.

The work is in defining your elements before you start writing and keeping them consistent between visits - cap, flue, brickwork, banding and base for a chimney; each elevation by floor for a facade. Consistent elements are what let a second inspection a year later be compared against the first instead of read on its own.

## What is in the document

- **1. Executive summary** - Overall condition for the asset's age and exposure, and the finding counts
- **2. Scope** - Exactly which elevations and elements were inspected, and from what range
- **3. Limitations** - No contact, nothing opened or removed, no testing, and what that excludes
- **4. Method and conditions** - Aircraft, sensor, operating category, clearances and conditions
- **5. Findings** - By element, each graded, with a table of what could not be assessed and how to
- **6. Defect schedule** - Reference, element, finding, grade and recommended action
- **7. Recommended actions** - Banded by urgency, naming what aerial imagery cannot resolve
- **Appendix A - Image index** - Element, view and range for each image, against its finding

## When it is used

To whoever has to decide whether to spend money on access - an owner, a managing agent, or the structural engineer they have retained. This is usually the document that justifies a scaffold or avoids one, so it is read closely and sometimes adversarially, and it should be written in the expectation that it will be.

## What the client does with it

The Not assessable table is the part that gets acted on first: it tells the client which elements still need a mobile platform or a rope access team, and what each would cost them to resolve. Where the report finds nothing urgent, it has saved the price of an access hire, and stating condition against the asset's age is what makes that finding credible rather than convenient.

## What it is not

It is a visual aerial survey, so it cannot report on structural adequacy, material condition below the surface, or flue integrity on a chimney. The template says so explicitly, because a reader who assumes otherwise will assume it in writing.

## Questions

### What kind of assets is it written for?

Anything surveyed externally and non-intrusively where the question is whether to spend money on access: facades, chimneys and stacks, towers and masts, tanks, bridges and industrial structures. The sections do not assume a building, which is what makes it the one to reach for when a job does not match a discipline-specific template.

### Why does it read as though it will be argued with?

Because it usually is. This is the document that justifies a scaffold or a rope access team, or avoids one, so it is read by someone with a budget decision riding on it. The limitations and Not assessable sections are what keep an honest survey from being read as a clean bill of health.

### Can it replace a close-up inspection?

No. It is the document that says whether a close-up inspection is warranted and where. Saying so explicitly is what protects you when the scaffold goes up and finds something the survey could never have seen.

## Documents used alongside it

- **Drone Roof Inspection Report Template** - The report a building owner can actually act on. https://canfly.io/toolkit/templates/drone-roof-inspection-report-template
- **Defect Severity Scale Template** - One grading scheme, meaning the same thing every time. https://canfly.io/toolkit/templates/defect-severity-scale-template
- **Solar PV Thermal Inspection Report Template** - Anomalies tied to a string, not a thermal image in a folder. https://canfly.io/toolkit/templates/solar-pv-thermal-inspection-report-template

These are our own documents. They contain no national zone data and none is required to use them. The canfly? map, the zone data and every export remain free.

---

**Citing this page:** canfly?, “Asset Inspection Report Template”, https://canfly.io/toolkit/templates/asset-inspection-report-template.
canfly? aggregates the official UAS geographical zones that EU and EEA states publish under
Regulation (EU) 2019/947, Article 15. It is not an air-traffic or flight-authorisation service;
critical flights must be confirmed against the national authority.