Anomalies tied to a string, not a thermal image in a folder
A report template for an aerial infrared thermographic survey of a photovoltaic array, written in general accordance with IEC 62446-3 - the international standard for PV thermography - and stating which of its requirements the survey met.
Every anomaly is referenced by physical position: block, row, string and module. That is the difference between a report an operations and maintenance contractor can send a technician out on, and a set of thermal images somebody has to re-interpret. Each entry carries its anomaly class and the measured temperature difference alongside the severity grade.
Section by section, as it ships.
| 1. Executive summary | Modules inspected, anomalies found, and the percentage affected |
| 2. Scope | Which blocks were surveyed, and the IEC 62446-3 requirements met |
| 3. Limitations | That thermography infers rather than diagnoses, and what needs electrical testing |
| 4. Method and conditions | Thermal and visual sensors, irradiance, ambient temperature, wind |
| 5. Findings | Each anomaly by block, row, string and module, with its class |
| 6. Anomaly schedule | Position, class, delta-T, grade and action, in one sortable table |
| 7. Recommended actions | Led by restoring outages, which is the recoverable revenue |
| Appendix A - Image index | Thermal and visual image pairs against each anomaly |
Straight after the survey, and to the operations and maintenance contractor or asset manager who will act on it rather than to the site owner alone. Timing matters more here than on any other job in the pack: a thermal anomaly only means something against the irradiance and load at the moment of the flight, so a report that lands three weeks later is far harder to act on and easier to dispute.
An asset manager converts the anomaly schedule into a work order and a revenue recovery estimate, because a string outage has a yield cost that can be calculated. A technician uses the position reference to walk to the module. Tie every anomaly to a string and an inverter and the next site visit is a repair rather than a second inspection, which is the whole commercial argument for the survey.
A thermal signature indicates where to investigate, not what is wrong. Root cause needs electrical testing at the module, and the template says so in its own limitations section rather than leaving the reader to infer a diagnosis the survey cannot support.
It is written to be compatible with how that standard expects a thermographic inspection to be reported - conditions at the time of the flight, anomaly classification, and the irradiance and load the measurements were taken under - without claiming certification on your behalf. If a client requires a report issued under the standard, the competency and the declaration are yours; the template is the structure.
Irradiance, ambient temperature, wind, and the inverter state at the time of the flight, plus the camera, its emissivity setting and the stand-off distance. Without those an anomaly is just a warm picture. The conditions table comes first in the template for that reason, and it is the part a client's own engineer checks before accepting a finding.
Yes. The structure is the same; what changes is the access and safety narrative and how a string is identified. Label modules by the site's own naming - inverter, string, position - rather than anything you invent on the day, so a maintenance crew can find the panel you flagged.
The rest of the job, in the order it happens.
The report a building owner can actually act on
Drone Inspection Report Template PackOne grading scheme, meaning the same thing every time
Drone Inspection Report Template PackFor the asset that justifies a scaffold, or avoids one
Drone Inspection Report Template Pack