Home › Toolkit › Templates › Solar PV Thermal Inspection Report Template

Solar PV Thermal Inspection Report Template

Anomalies tied to a string, not a thermal image in a folder

Editable .docxIn the Drone Inspection Report Template PackAfter the flight

What it is

A report template for an aerial infrared thermographic survey of a photovoltaic array, written in general accordance with IEC 62446-3 - the international standard for PV thermography - and stating which of its requirements the survey met.

Every anomaly is referenced by physical position: block, row, string and module. That is the difference between a report an operations and maintenance contractor can send a technician out on, and a set of thermal images somebody has to re-interpret. Each entry carries its anomaly class and the measured temperature difference alongside the severity grade.

What is in the document

Section by section, as it ships.

1. Executive summaryModules inspected, anomalies found, and the percentage affected
2. ScopeWhich blocks were surveyed, and the IEC 62446-3 requirements met
3. LimitationsThat thermography infers rather than diagnoses, and what needs electrical testing
4. Method and conditionsThermal and visual sensors, irradiance, ambient temperature, wind
5. FindingsEach anomaly by block, row, string and module, with its class
6. Anomaly schedulePosition, class, delta-T, grade and action, in one sortable table
7. Recommended actionsLed by restoring outages, which is the recoverable revenue
Appendix A - Image indexThermal and visual image pairs against each anomaly

When it is used

Straight after the survey, and to the operations and maintenance contractor or asset manager who will act on it rather than to the site owner alone. Timing matters more here than on any other job in the pack: a thermal anomaly only means something against the irradiance and load at the moment of the flight, so a report that lands three weeks later is far harder to act on and easier to dispute.

What the client does with it

An asset manager converts the anomaly schedule into a work order and a revenue recovery estimate, because a string outage has a yield cost that can be calculated. A technician uses the position reference to walk to the module. Tie every anomaly to a string and an inverter and the next site visit is a repair rather than a second inspection, which is the whole commercial argument for the survey.

What it is not

A thermal signature indicates where to investigate, not what is wrong. Root cause needs electrical testing at the module, and the template says so in its own limitations section rather than leaving the reader to infer a diagnosis the survey cannot support.

Questions

Does it follow IEC 62446-3?

It is written to be compatible with how that standard expects a thermographic inspection to be reported - conditions at the time of the flight, anomaly classification, and the irradiance and load the measurements were taken under - without claiming certification on your behalf. If a client requires a report issued under the standard, the competency and the declaration are yours; the template is the structure.

What has to be recorded for a thermal finding to mean anything?

Irradiance, ambient temperature, wind, and the inverter state at the time of the flight, plus the camera, its emissivity setting and the stand-off distance. Without those an anomaly is just a warm picture. The conditions table comes first in the template for that reason, and it is the part a client's own engineer checks before accepting a finding.

Can I use it for rooftop arrays as well as ground-mount?

Yes. The structure is the same; what changes is the access and safety narrative and how a string is identified. Label modules by the site's own naming - inverter, string, position - rather than anything you invent on the day, so a maintenance crew can find the panel you flagged.

Documents used alongside it

The rest of the job, in the order it happens.